iec60870_5_104 21.5.26

dotnet add package iec60870_5_104 --version 21.5.26
NuGet\Install-Package iec60870_5_104 -Version 21.5.26
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="iec60870_5_104" Version="21.5.26" />
For projects that support PackageReference, copy this XML node into the project file to reference the package.
paket add iec60870_5_104 --version 21.5.26
#r "nuget: iec60870_5_104, 21.5.26"
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
// Install iec60870_5_104 as a Cake Addin
#addin nuget:?package=iec60870_5_104&version=21.5.26

// Install iec60870_5_104 as a Cake Tool
#tool nuget:?package=iec60870_5_104&version=21.5.26

IEC 60870-5-104 Protocol

RTU Server Simulator, Master Client Simulator, Windows and Linux POSIX ARM, IEC104 Source Code in C, C++, C# .NET Programming

IEC 60870-5 part 104 enables communication between IED, RTU control station and substation via a standard TCP/IP network. The TCP protocol is used for connection-oriented secure data transmission.

IEC 60870-5-104 Protocol

Make your RTU, protocol converter, Gateway, HMI, Data concentrator compatible with iec 104.

Download Evaluation Kit - IEC 104 Development Bundle

In the Development Bundle, We included IEC 104 Protocol Server Client Simulator, Windows and Linux SDK, C# projects, Doxygen documentation and Raspberry Pi, BeagleBone Demo library.

IEC 60870-5-104 Source Code Windows C C++ C# .net Linux Arm POSIX C C++

The most complete implementation of IEC 104 protocol stack including File transfer (Monitor and Control Direction), Directory Commnads, Supports all type of Monitoring, command , parameter ASDUs.

Low memory footprint, easy start on any hardware platform, can operate with or without an operating system, delivered as a source code,

high configurability allows to use required features only, royalty-free licensing.

IEC 60870-5-104 Code Windows C C++ C# .net Linux Arm POSIX

Salient Features

  • Written in ANSI-Standard C Source Code, under a strict corporate coding standard, and supports C++, C#

  • Transparent licensing scheme - No hidden costs, No deferred payments.

  • High performance, robust and scalable architecture

  • Provides a simple method for systems Integrators and OEMs to utilize standard tools to implement their systems

  • Our stacks are fully compliant with "POSIX" and tested in ubuntu, feroda, Debian, QNX, Linux Embedded OS and Various Cross compiler tool chains.

  • Our all protocol stack supports "POSIX compliant operating system"

  • Context-based event-driven model

  • Multiple Server and Client Simulation

  • In a Single Server(link) simulate Multiple Stations (Common Address / Station Address)

  • Supports Background Scan, Cyclic Data Transmission, Double Transmission, Redundancy and File transfer.

  • Communication with redundant control systems and interruption-free switch over between redundant systems

  • Supports "Select-Before-Operate" and "Direct-Execute" command execution modes

  • In IEC 60870-5-104 Client Side, Data Mode and Test mode connection type available.

  • Source Code Library allows a fast and cost efficient implementation

  • APIs are designed to be very easy to use and flexible

Knowledge Base - Interoperability

IEC 60870-5-104 Protocol Server Interoperability

IEC 60870-5-104 protocol Client Interoperability

IEC 60870-5 part 104 Windows C C++ C# .NET Programming

IEC 60870-5-104 Demo Win DLL includes simple (Server & Client C programs, c# .net )example using a Command window and command line inputs.

The source code will allow you to quickly compile your own examples with the features of your existing development environment to work with our IEC 60870-5-104 DLL..IEC 104 Windows SDK contains Win DLL (precompiled library), Static link lib, Demo IEC104 Server & Client programs, Visual Studio Demo console project files, Doxygen .

We used Visual studio compiler to create the dll, sample test projects.

IEC 60870-5-104 Windows C C++ C# .NET

IEC 60870-5-104 Protocol Linux Development POSIX C C++ ARM

IEC 104 Demo Linux Shared Library includes simple (Server & Client C programs )example using a Command window and command line inputs.

The source code will allow you to quickly compile your own examples with the features of your existing development environment to work with our IEC 60870-5-104 library.

IEC 60870-5-104 Linux SDK contains Shared Library(.a) (precompiled library), Static link lib, Demo IEC104 Server & Client programs, CodeBlock Demo console project files, Doxygen .

We used gcc compiler to create the Shared Library, sample test projects.

IEC 60870-5-104 Protocol Linux C C++ POSIX

IEC 60870-5-104 RTU IED Server Simulator

Complete Simulation of IEC 104 Server as per Protocol Standard including File transfer (Both Monitoring and control direction).

IEC 60870-5-104 Protocol RTU IED Server Simulator

IEC 60870-5-104 Protocol Client Master Simulator

Complete Simulation of IEC 104 Client as per Protocol Standard including File transfer (Both Monitoring and control direction).

IEC 60870-5 part 104 Protocol Client Master Simulator

IEC 60870-5 part 104 Protocol Video Tutorial

Download Evaluation Kit - IEC 104 Protocol Development Bundle

In the Development Bundle, We included IEC 60870-5 part 104 Protocol Server Client Simulator, Windows and Linux SDK, C# projects, Doxygen documentation and Raspberry Pi, BeagleBone Demo library.

Product Compatible and additional computed target framework versions.
.NET net5.0 was computed.  net5.0-windows was computed.  net6.0 was computed.  net6.0-android was computed.  net6.0-ios was computed.  net6.0-maccatalyst was computed.  net6.0-macos was computed.  net6.0-tvos was computed.  net6.0-windows was computed.  net7.0 was computed.  net7.0-android was computed.  net7.0-ios was computed.  net7.0-maccatalyst was computed.  net7.0-macos was computed.  net7.0-tvos was computed.  net7.0-windows was computed.  net8.0 was computed.  net8.0-android was computed.  net8.0-browser was computed.  net8.0-ios was computed.  net8.0-maccatalyst was computed.  net8.0-macos was computed.  net8.0-tvos was computed.  net8.0-windows was computed. 
.NET Core netcoreapp2.0 was computed.  netcoreapp2.1 was computed.  netcoreapp2.2 was computed.  netcoreapp3.0 was computed.  netcoreapp3.1 was computed. 
.NET Standard netstandard2.0 is compatible.  netstandard2.1 was computed. 
.NET Framework net461 was computed.  net462 was computed.  net463 was computed.  net47 was computed.  net471 was computed.  net472 was computed.  net48 was computed.  net481 was computed. 
MonoAndroid monoandroid was computed. 
MonoMac monomac was computed. 
MonoTouch monotouch was computed. 
Tizen tizen40 was computed.  tizen60 was computed. 
Xamarin.iOS xamarinios was computed. 
Xamarin.Mac xamarinmac was computed. 
Xamarin.TVOS xamarintvos was computed. 
Xamarin.WatchOS xamarinwatchos was computed. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.
  • .NETStandard 2.0

    • No dependencies.

NuGet packages

This package is not used by any NuGet packages.

GitHub repositories

This package is not used by any popular GitHub repositories.

Version Downloads Last updated
21.5.26 280 6/30/2023
21.5.25 326 2/20/2023
21.5.23 461 10/29/2022
21.5.18 557 6/30/2022
21.5.13 522 3/1/2022
21.5.10 601 11/2/2021

Immp : Place "iec104win32d.dll" from "packages\iec60870_5_104.21.0x.0xx\runtime\iec104win32d.dll" folder to your application output directory.
This package includes x86 binaries. You must specify the target platform in your IDE (i.e. you cannot use "AnyCPU / x64").
Both iec 104 server and client - file transfer (Monitoring and control direction) implemented.
All types of ASDU - Monitoring and control, Parameter typeids implemented and tested.
Technical support mail to support@freyrscada.com
iec104 server test program:
https://www.freyrscada.com/nuget/iec60870-5-104/iec104servertest.cs
iec104 server test program:
https://www.freyrscada.com/nuget/iec60870-5-104/iec104clienttest.cs